| BOF00 |
Logical "0" or "Off" |
Parameters Available from Menu Only |
| BOF01 |
Logical "1" or "On" |
Parameters Available from Menu Only |
| BOF02 |
Logical "0" or according to BIFs |
Parameters Available from Menu Only |
| BOF03 |
Fault (0 = True = Fault) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF04 |
Ready to start (waiting for the start command) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF05 |
Ready to operate (waiting for enable) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF06 |
Run |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF07 |
Turn auxiliary equipment "On" |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF08 |
AC supply voltage available (armature and field) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF09 |
Line contactor controlOFF = switch-on inhibit (low active) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF10 |
Line contactor OFF = Estop (low active) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF11 |
Status signal from BIF55 "line contactor closed" |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF12 |
Ramp-function generator active |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF13 |
Reverse direction of rotation |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF14 |
Switch-on command for the holding or operating brake (low active) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF15 |
Ia > Ix (Ix is set using P391, hysteresis P374) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF16 |
n < nx1 (nx1 is set using P373, hysteresis P374) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF17 |
n < nx2 (nx2 is set using P376, hysteresis P377) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF18 |
n < nx3 (nx3 is set using P379, hysteresis P380) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF19 |
n < nx4 (nx4 is set using P382, hysteresis P383) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF20 |
n < nx5 (nx5 is set using P385, hysteresis P386) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF21 |
n < nmin (nmin is set using P370, hysteresis P371) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF22 |
Reference speed reached (setpoint-feedback < P362) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF23 |
Speed < maximum speed |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF24 |
Warning (low active) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF25 |
Warning, motor overload, i.e., W01 or W05 or W06 (low active) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF26 |
Warning, converter overload (low active) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF27 |
Converter cooling faulted |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF28 |
I field < I fmin (low active) (I fmin is set using P394, hysteresis P395) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF29 |
Ia = I limit (actual current limit reached) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF30 |
Field reversing contactor 1 "On" (main contactor) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF31 |
Field reversing contactor 2 "On" (reversing contactor) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF32 |
Torque direction change signal |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF33 |
Power section warm (European design only) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF34 |
General purpose limit detector 1 |
Limit Detect #1: A and B are compared with result to BOF34 |
| BOF35 |
General purpose limit detector 2 |
Limit Detect #2: A and B are compared with result to BOF35 |
| BOF36 |
Coast Stop (Stop 2) is active (Version 2.3) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |
| BOF37 |
Quick Stop (Stop 3) is active (Version 2.3) |
Standard Status Words (ZSW, ZSW1, and ZSW2) |