| BIF00 |
No function |
Parameters Available from Menu Only |
| BIF01 |
Reserved for future use |
Parameters Available from Menu Only |
| BIF02 |
Normal Stop |
Parameters Available from Menu Only |
| BIF03 |
Coast Stop |
Parameters Available from Menu Only |
| BIF04 |
Quick stop |
Speed controller |
| BIF05 |
Fault reset |
Parameters Available from Menu Only |
| BIF06 |
Enable Technology controller |
Technology Controller |
| BIF07 |
Enable speed controller |
Speed controller |
| BIF08 |
Enable CEMF controller |
EMF Voltage Controller |
| BIF09 |
Enable ramp generator |
Ramp function generator |
| BIF10 |
Ramp generator stop |
Ramp function generator |
| BIF11 |
Reference enable |
Reference selections |
| BIF12 |
Oscillation function |
Reference selections |
| BIF13 |
Jog |
Reference selections |
| BIF14 |
Jog and bypass the ramp generator |
Reference selections |
| BIF15 |
Thread |
Reference selections |
| BIF16 |
Thread and bypass the ramp generator |
Reference selections |
| BIF17 |
Fixed reference setpoint |
Reference selections |
| BIF18 |
Fixed reference setpoint bypassing the ramp generator |
Reference selections |
| BIF19 |
Additional reference before the Technology controller |
Technology Controller |
| BIF20 |
Additional reference before the ramp generator |
Reference selections |
| BIF21 |
Additional reference before the speed controller |
Reference limiter |
| BIF22 |
Additional reference before torque limiting |
Torque Limiter |
| BIF23 |
Additional reference before the current controller |
Current Controller |
| BIF24 |
Selection of second set of main reference limits |
Reference selections |
| BIF25 |
MOP manual / automatic |
Motor POT (MOP) Function |
| BIF26 |
MOP increase |
Motor POT (MOP) Function |
| BIF27 |
MOP decrease |
Motor POT (MOP) Function |
| BIF28 |
MOP reverse polarity direction switch |
Motor POT (MOP) Function |
| BIF29 |
MOP positive polarity direction push-button |
Motor POT (MOP) Function |
| BIF30 |
MOP negative polarity direction push-button |
Motor POT (MOP) Function |
| BIF31 |
Ramp generator set #2 |
Ramp function generator |
| BIF32 |
Ramp generator set #3 |
Ramp function generator |
| BIF33 |
Parameter set #2 active |
Parameters Available from Menu Only |
| BIF34 |
Parameter set #3 active |
Parameters Available from Menu Only |
| BIF35 |
Parameter set #4 active |
Parameters Available from Menu Only |
| BIF36 |
Technology controller droop |
Technology Controller |
| BIF37 |
Enable speed controller droop |
Speed controller |
| BIF38 |
Switch the speed controller from PI to P controller |
Speed controller |
| BIF39 |
Enabled inertia compensation |
Torque Compensation |
| BIF40 |
Speed feedback polarity reversal |
Speed controller |
| BIF41 |
Master / Slave selection |
Speed controller |
| BIF42 |
Torque limit set selection |
Torque Limiter |
| BIF43 |
Selecting the main reference (Terminals 4 and 5) |
Main Reference |
| BIF44 |
Selecting the main speed feedback (Terminals 60 to 64) |
Main Feedback |
| BIF45 |
Selecting the analog input 1 (Terminals 6 and 7) |
Analog Input #1 |
| BIF46 |
Selecting the analog input 2 (Terminals 8 and 9) |
Analog Input #2 |
| BIF47 |
Selecting the analog input3 (Terminals 10 and 11) |
Analog Input #3 |
| BIF48 |
Main reference polarity |
Main Reference |
| BIF49 |
Main analog speed feedback polarity |
Main Feedback |
| BIF50 |
Analog input 1 polarity |
Analog Input #1 |
| BIF51 |
Analog input 2 polarity |
Analog Input #2 |
| BIF52 |
Analog input 3 polarity |
Analog Input #3 |
| BIF53 |
External fault (low active) |
Parameters Available from Menu Only |
| BIF54 |
External warning (low active) |
Parameters Available from Menu Only |
| BIF55 |
M contactor status signal |
Parameters Available from Menu Only |
| BIF56 |
Forced field economizing |
Field Controller |
| BIF57 |
Speed direction change |
Parameters Available from Menu Only |
| BIF58 |
Regenerative braking stop |
Parameters Available from Menu Only |
| BIF59 |
Field current less than minimum field current |
Parameters Available from Menu Only |
| BIF60 |
Torque Reversal Interlock |
Current Controller |
| BIF61 |
Set binary output 1 |
Binary Output #1 |
| BIF62 |
Set binary output 2 |
Binary Output #2 |
| BIF63 |
Set binary output 3 |
Binary Output #3 |
| BIF64 |
Set binary output 4 |
Binary Output #4 |
| BIF65 |
Programmable switching function 1 |
Switch #1: Switch between P656 and P657 at K242 |
| BIF66 |
Programmable switching function 2 |
Switch #2: Switch between P666 and P667 as K234 |
| BIF67 |
Programmable switching function 3 |
Switch #3: Switch between P676 and P677 at K154 |
| BIF68 |
Preset MOP |
Motor POT (MOP) Function |
| BIF69 |
Ramp-up Integrator Changeover Enable (Version 2.2) |
Ramp function generator |