Connector Description Block
BIF00 No function Parameters Available from Menu Only
BIF01 Reserved for future use Parameters Available from Menu Only
BIF02 Normal Stop Parameters Available from Menu Only
BIF03 Coast Stop Parameters Available from Menu Only
BIF04 Quick stop Speed controller
BIF05 Fault reset Parameters Available from Menu Only
BIF06 Enable Technology controller Technology Controller
BIF07 Enable speed controller Speed controller
BIF08 Enable CEMF controller EMF Voltage Controller
BIF09 Enable ramp generator Ramp function generator
BIF10 Ramp generator stop Ramp function generator
BIF11 Reference enable Reference selections
BIF12 Oscillation function Reference selections
BIF13 Jog Reference selections
BIF14 Jog and bypass the ramp generator Reference selections
BIF15 Thread Reference selections
BIF16 Thread and bypass the ramp generator Reference selections
BIF17 Fixed reference setpoint Reference selections
BIF18 Fixed reference setpoint bypassing the ramp generator Reference selections
BIF19 Additional reference before the Technology controller Technology Controller
BIF20 Additional reference before the ramp generator Reference selections
BIF21 Additional reference before the speed controller Reference limiter
BIF22 Additional reference before torque limiting Torque Limiter
BIF23 Additional reference before the current controller Current Controller
BIF24 Selection of second set of main reference limits Reference selections
BIF25 MOP manual / automatic Motor POT (MOP) Function
BIF26 MOP increase Motor POT (MOP) Function
BIF27 MOP decrease Motor POT (MOP) Function
BIF28 MOP reverse polarity direction switch Motor POT (MOP) Function
BIF29 MOP positive polarity direction push-button Motor POT (MOP) Function
BIF30 MOP negative polarity direction push-button Motor POT (MOP) Function
BIF31 Ramp generator set #2 Ramp function generator
BIF32 Ramp generator set #3 Ramp function generator
BIF33 Parameter set #2 active Parameters Available from Menu Only
BIF34 Parameter set #3 active Parameters Available from Menu Only
BIF35 Parameter set #4 active Parameters Available from Menu Only
BIF36 Technology controller droop Technology Controller
BIF37 Enable speed controller droop Speed controller
BIF38 Switch the speed controller from PI to P controller Speed controller
BIF39 Enabled inertia compensation Torque Compensation
BIF40 Speed feedback polarity reversal Speed controller
BIF41 Master / Slave selection Speed controller
BIF42 Torque limit set selection Torque Limiter
BIF43 Selecting the main reference (Terminals 4 and 5) Main Reference
BIF44 Selecting the main speed feedback (Terminals 60 to 64) Main Feedback
BIF45 Selecting the analog input 1 (Terminals 6 and 7) Analog Input #1
BIF46 Selecting the analog input 2 (Terminals 8 and 9) Analog Input #2
BIF47 Selecting the analog input3 (Terminals 10 and 11) Analog Input #3
BIF48 Main reference polarity Main Reference
BIF49 Main analog speed feedback polarity Main Feedback
BIF50 Analog input 1 polarity Analog Input #1
BIF51 Analog input 2 polarity Analog Input #2
BIF52 Analog input 3 polarity Analog Input #3
BIF53 External fault (low active) Parameters Available from Menu Only
BIF54 External warning (low active) Parameters Available from Menu Only
BIF55 M contactor status signal Parameters Available from Menu Only
BIF56 Forced field economizing Field Controller
BIF57 Speed direction change Parameters Available from Menu Only
BIF58 Regenerative braking stop Parameters Available from Menu Only
BIF59 Field current less than minimum field current Parameters Available from Menu Only
BIF60 Torque Reversal Interlock Current Controller
BIF61 Set binary output 1 Binary Output #1
BIF62 Set binary output 2 Binary Output #2
BIF63 Set binary output 3 Binary Output #3
BIF64 Set binary output 4 Binary Output #4
BIF65 Programmable switching function 1 Switch #1: Switch between P656 and P657 at K242
BIF66 Programmable switching function 2 Switch #2: Switch between P666 and P667 as K234
BIF67 Programmable switching function 3 Switch #3: Switch between P676 and P677 at K154
BIF68 Preset MOP Motor POT (MOP) Function
BIF69 Ramp-up Integrator Changeover Enable (Version 2.2) Ramp function generator